Skip to content

Chargers

65W Retractable-Cable Charger, UK Plug, Single Colour

TG65R-ACC

65 W wall charger with a retractable USB-C cable in a single-colour housing, UK plug. Port configuration and the certifications held for this variant are still to be confirmed by the client.

  • 65 W
  • Retractable cable

MOQ 500 pcsSample lead time 3–5 daysProduction time 25–35 days

Questions? Chat on WhatsApp

Overview

A 65 W wall charger with a retractable USB-C cable built into the housing, so the output lead travels with the unit instead of being lost or left behind. The body is moulded in a single colour for private-label programmes.

This page covers the UK plug variants. The shared electrical datasheet is document TGITION_TG65R-ACC Rev 1.0; port configuration, plug detail and the certifications held for this variant are still to be confirmed by the client and are marked below.

  • Retractable USB-C cable rated to the full 65 W (20 V / 3.25 A)
  • Wide-range 100–240 V AC input with a 90–264 V AC operating window
  • Standby power consumption of 0.30 W
  • Hiccup-mode short-circuit protection with automatic recovery

Specifications

Input

Input100–240 V AC, 50/60 Hz; operating range 90–264 V AC, 47–63 Hz; 1,500 mA max at nominal input and rated load

Output

Rated output65 W (retractable USB-C cable: 5 V 3 A, 9 V 3 A, 12 V 3 A, 15 V 3 A, 20 V 3.25 A)
Output5 V 3 A (15 W); 9 V 3 A (27 W); 12 V 3 A (36 W); 15 V 3 A (45 W); 20 V 3.25 A (65 W)
Ripple & noise200 mVp-p maximum, 20 MHz bandwidth
Standby power0.30 W maximum
EfficiencyMinimum average efficiency 81.39–88.00% across the rated outputs (ERP3 referenced)

Protection

ProtectionsShort circuit (hiccup mode, automatic recovery); over-current: ≤4.2 A at 5/9/12/15 V, ≤3.5 A at 15 V 2.5 A, ≤3.15 A at 20 V 2.25 A, ≤4.55 A at 20 V 3.25 A

Environmental

Operating conditionsOperating 0–25 °C at full load; storage −20 to 85 °C; 5–95% RH; up to 2,000 m

Compliance & reliability

TestConditionResult / scope
Burn-inburned in for 2 hours at 25 °C at full load100% of units
Input cyclinginput settings cycled through 90 / 115 / 230 / 264 V AC100% of units
Drop120 cm drop onto concrete across all six facesSampling

EN55035:2017 (EMS); EN55032 / EN61000-3-2 / EN61000-3-3 (EMI); surge 1 kV differential mode, Class II; ESD 8 kV air / 4 kV contact; hi-pot 3200 V AC / 5 mA / 60 s

Ordering & packaging

Commercial terms

MOQ500 pcs
Sample lead time3–5 days
Production lead time25–35 days

Other versions

Product details

Need this model customized?

Tell us your voltage, plug and quantity. Engineering reply within 1 business day.

Reply within 1 business dayNDA available on request