Skip to content

Power Inverters

6.2kW Single-Phase Hybrid Storage Inverter

TG6200SP-EU

6.2 kW single-phase hybrid inverter for household energy storage: 6,500 W PV input, 51.2 V battery, 10 ms backup transfer and parallel capability up to six units.

  • 6.2 kW
  • Single phase

MOQ 500 pcsSample lead time 3–5 daysProduction time 25–35 days

Questions? Chat on WhatsApp

Overview

A 6.2 kW single-phase hybrid inverter for a household energy storage system: photovoltaic input, a 51.2 V battery, the grid and backup loads are managed by one wall-mounted unit. It runs off-grid, grid-connected or with no battery at all, and up to six units can be paralleled into a 37.2 kW group.

  • 200% emergency peak output for 5 s (12,000 VA)
  • 10 ms UPS transfer for backup loads
  • CT anti-backflow with zero-feed-in protection
  • Peak shaving and smart time-of-use power management

Specifications

General

Battery51.2 Vdc rated; 40–60 Vdc range; 44 V minimum start; lead-acid or lithium; 100 A charge / 135 A discharge
Parallel capability1–6 units, up to 37.2 kW per group

Input

InputPV: 6,500 W max DC, 90–500 V, single MPPT 27 A. AC: 170–280 V AC, 47–55 / 57–65 Hz, 40 Aac max

Output

Rated output6,200 W / 6,200 VA rated; 12,000 VA peak for 5 s
Output230 V AC, 50/60 Hz, power factor 1, L+N+PE; off-grid / grid-connected / batteryless operation
EfficiencyMax efficiency (battery to load) >94.5%

Protection

ProtectionsMains overload (40 A circuit breaker), AC reverse feed, battery short circuit (fuse), AC output short circuit, wiring protection; 10 ms typical transfer time

Environmental

Operating conditions−10 to 55 °C (>45 °C derating), 5–95% humidity, up to 4,000 m (no derating below 2,000 m), IP21, ≤60 dB, forced air cooling

Physical

Housing dimensions428 × 280 × 110 mm (L × W × H)
Net weight8.2 kg
Plug / connector typesL+N+PE AC connection; PV and battery terminals; USB / RS485 / WiFi communication
Dimensions / weight428 × 280 × 110 mm; 8.2 kg; IP21; ≤60 dB; forced air cooling (variable speed)

Compliance & reliability

CE (IEC62109-1, -2); IEC61000, C2

Ordering & packaging

Commercial terms

MOQ500 pcs
Sample lead time3–5 days
Production lead time25–35 days

Need this model customized?

Tell us your voltage, plug and quantity. Engineering reply within 1 business day.

Reply within 1 business dayNDA available on request